J Med Microbiol ; 72(2)2023 Feb.
Article in English | MEDLINE | ID: covidwho-2282648

ABSTRACT

Introduction. Starting in December, 2020, the ID NOW was implemented throughout the province of Alberta, Canada (population 4.4 million) in various settings.Gap statement. ID NOW's test performance with SARS-CoV-2 Omicron variant BA.1 is unknown.Aim. To assess the ID NOW performance among symptomatic individuals during the BA.1 Omicron wave and compare it to previous SARS-CoV-2 variant waves.Methodology. The ID NOW was assessed in two locations among symptomatic individuals: rural hospitals and community assessment centres (AC) during the period 5-18 January 2022. Starting 5 January, Omicron represented >95 % of variants detected in our population. For every individual tested, two swabs were collected: one for ID NOW testing and the other for either reverse-transcriptase polymerase chain reaction (RT-PCR) confirmation of negative ID NOW results or for variant testing of positive ID NOW results.Results. A total of 3041 paired samples were analysed (1139 RT-PCR positive). From this, 1873 samples were from 42 COVID-19 AC and 1168 from 69 rural hospitals. ID NOW sensitivity for symptomatic individuals presenting to community AC and rural hospitals was 96.0 % [95 % confidence interval (CI) 94.5-97.3 %, n=830 RT-PCR positive], and 91.6 % (95 % CI 87.9-94.4 %, n=309 RT-PCR positive), respectively. SARS-CoV-2 positivity rate was very high for both populations (44.3 % at AC, 26.5 % in hospital).Conclusions. Sensitivity of ID NOW SARS-CoV-2, compared to RT-PCR, is very high during the BA.1 Omicron wave, and is significantly higher when compared to previous SARS-CoV-2 variant waves.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , COVID-19/epidemiology , SARS-CoV-2/genetics , Canada , Hospitals
2.
Clin Microbiol Infect ; 2022 Sep 10.
Article in English | MEDLINE | ID: covidwho-2235929

ABSTRACT

OBJECTIVE: Diagnostic evaluation of the ID NOW coronavirus disease 2019 (COVID-19) assay in various real-world settings among symptomatic and asymptomatic individuals. METHODS: Depending on the setting, the ID NOW testing was performed using oropharyngeal swabs (OPSs) taken from patients with symptoms suggestive of COVID-19, asymptomatic close contacts, or asymptomatic individuals as part of outbreak point prevalence screening. From January to April 2021, a select number of sites switched from using OPS to combined oropharyngeal and nasal swab (O + NS) for ID NOW testing. For every individual tested, two swabs were collected by a health care worker: one swab (OPS or O + NS) for ID NOW testing and a separate swab (OPS or nasopharyngeal swab) for RT-PCR. RESULTS: A total of 129 112 paired samples were analysed (16 061 RT-PCR positive). Of these, 81 697 samples were from 42 COVID-19 community collection sites, 16 924 samples were from 69 rural hospitals, 1927 samples were from nine emergency shelters and addiction treatment facilities, 23 802 samples were from six mobile units that responded to 356 community outbreaks, and 4762 O + NS swabs were collected from three community collection sites and one emergency shelter. The ID NOW assay sensitivity was the highest among symptomatic individuals presenting to community collection sites (92.5%; 95% CI, 92.0-93.0%) and the lowest for asymptomatic individuals associated with community outbreaks (73.9%; 95% CI, 69.8-77.7%). Specificity was >99% in all populations tested. DISCUSSION: The sensitivity of ID NOW severe acute respiratory syndrome coronavirus 2 testing is the highest when used in symptomatic community populations not seeking medical care. Sensitivity and positive predictive value drop by approximately 10% when tested on asymptomatic populations. Using combined oropharyngeal and nasal swabs did not improve the performance of ID NOW assay.

3.
Expert Rev Mol Diagn ; 22(8): 797-809, 2022 08.
Article in English | MEDLINE | ID: covidwho-2017392

ABSTRACT

INTRODUCTION: Detection of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) has been critical to support and management of the COVID-19 pandemic. Point of care testing (POCT) for SARS-CoV-2 has been a widely used tool for detection of SARS-CoV-2. AREAS COVERED: POCT nucleic acid amplification tests (NAATs) and rapid antigen tests (RATs) have been the most readily used POCT for SARS-CoV-2. Here, current knowledge on the utility of POCT NAATs and RATs for SARS-CoV-2 are reviewed and discussed alongside aspects of quality assurance factors that must be considered for successful and safe implementation of POCT. EXPERT OPINION: Use cases for implementation of POCT must be evidence based, regardless of the test used. A quality assurance framework must be in place to ensure accuracy and safety of POCT.


Subject(s)
COVID-19 , COVID-19/diagnosis , COVID-19 Testing , Humans , Pandemics , Point-of-Care Systems , Point-of-Care Testing , SARS-CoV-2 , Sensitivity and Specificity
5.
J Clin Microbiol ; 59(11): e0141121, 2021 10 19.
Article in English | MEDLINE | ID: covidwho-1480238

ABSTRACT

Frequent screening of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) among asymptomatic populations using antigen-based point-of-care tests (APOCTs) is occurring globally with limited clinical performance data. The positive predictive value (PPV) of two APOCTs used in the asymptomatic screening of SARS-CoV-2 among health care workers (HCWs) at continuing care (CC) sites across AB, Canada, was evaluated. Between 22 February and 2 May 2021, CC sites implemented SARS-CoV-2 voluntary screening of their asymptomatic HCWs. On-site testing with Abbott Panbio or BD Veritor occurred on a weekly or twice-weekly basis. Positive APOCTs were confirmed with a real-time reverse transcriptase PCR (rRT-PCR) reference method. A total of 71,847 APOCTs (17,689 Veritor and 54,158 Panbio) were performed among 369 CC sites. Eighty-seven (0.12%) APOCTs were positive, of which 39 (0.05%) were confirmed as true positives using rRT-PCR. Use of the Veritor and Panbio resulted in 76.6% and 30.0% false-positive detection, respectively (P < 0.001). This corresponded to PPVs of 23.4 and 70.0% for the Veritor and Panbio, respectively. Frequent screening of SARS-CoV-2 among asymptomatic HCWs in CC, using APOCTs, resulted in a very low detection rate and a high rate of detection of false positives. Careful assessment of the risks versus benefits of APOCT programs and the prevalence of infection in this population needs to be thoroughly considered before implementation.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Point-of-Care Testing , Predictive Value of Tests , Sensitivity and Specificity
6.
Eur J Clin Microbiol Infect Dis ; 40(8): 1721-1726, 2021 Aug.
Article in English | MEDLINE | ID: covidwho-1141451

ABSTRACT

SARS-CoV-2 antigen tests used at the point-of-care, such as the Abbott Panbio, have great potential to help combat the COVID-19 pandemic. The Panbio is Health Canada approved for the detection of SARS-CoV-2 in symptomatic individuals within the first 7 days of COVID-19 symptom onset(s). Symptomatic adults recently diagnosed with COVID-19 in the community were recruited into the study. Paired nasopharyngeal (NP), throat, and saliva swabs were collected, with one paired swab tested immediately with the Panbio, and the other transported in universal transport media and tested using real-time reverse-transcriptase polymerase chain reaction (RT-PCR). We also prospectively evaluated results from assessment centers within the community. For those individuals, an NP swab was collected for Panbio testing and paired with RT-PCR results from parallel NP or throat swabs. One hundred and forty-five individuals were included in the study. Collection of throat and saliva was stopped early due to poorer performance (throat sensitivity 57.7%, n=61, and saliva sensitivity 2.6%, n=41). NP swab sensitivity was 87.7% [n=145, 95% confidence interval (CI) 81.0-92.7%]. There were 1641 symptomatic individuals tested by Panbio in assessment centers with 268/1641 (16.3%) positive for SARS-CoV-2. There were 37 false negatives and 2 false positives, corresponding to a sensitivity and specificity of 86.1% [95% CI 81.3-90.0%] and 99.9% [95% CI 99.5-100.0%], respectively. The Panbio test reliably detects most cases of SARS-CoV-2 from adults in the community setting presenting within 7 days of symptom onset using nasopharyngeal swabs. Throat and saliva swabs are not reliable specimens for the Panbio.


Subject(s)
COVID-19 Testing , COVID-19/diagnosis , Nasopharynx/virology , Pharynx/virology , Saliva/virology , Adult , Aged , Aged, 80 and over , Canada , False Negative Reactions , False Positive Reactions , Female , Humans , Male , Middle Aged , Sensitivity and Specificity , Specimen Handling